Apply as sales agent

Blog

2.13.2 Output Channel Diagnostics (PB) on Injection Molding Machine

Path to get to Output Channel Diagnostics screen on a injection molding machine: F10 next –> F4 IO –> F2 PB –> F6 set PB If the PCB board is malfunctioning, you can transfer the malfunction point to the unused input point.Please consult the producer for the password.

Read more

2.13.1 Input Channel Diagnostics (PB) on Injection Molding Machine

Path to get to Input Channel Diagnostics (PB) screen: F10 next –> F4 IO –> F2 PB –> F2 PB1   PB2、PB3、PB4 and PB1picture and function are similar. PB2、PB3、PB4 and PB1picture and function are similar.   You can use this display screen to ensure the connection between the controller and […]

Read more

2.12.2 Data Adjustment Settings of Injection Molding Machine

  Path: F10 next –> F3 adjustment –> F3 DA1   DA2,DA3,DA4 and DA1 picture and function are similar   Output force: DA correction during the test output, the corresponding channel’s output continued to the timing, when the timing has reach the limit , the output will automatically be cut […]

Read more

2.12.1 Adjustment settings on Powerjet Injection Molding Machine

Path: F10 next –> F3 adjustment –> F2AD The replacement of foot position or modify some of the mechanical parts, so re-location of the zero correction is needed (in manual mode only):   1. Please insert the password   2. Please switch the part to zero according to the requirement […]

Read more

2.11.5 Monitor Parameters Settings of Injection Molding Machine

Path: F10 next –> F2 monitor –> F7 parameters F7 parameters The value could be set according to the actual production demand.

Read more

2.11.4 Monitoring Counting Settings

Path: F10 next –> F2 monitor –> F6 counting Total amount of mold open zero-mode: If you want to enter a zero mode after the opening mold, please select“use”, then press key to clear and recount the total. Total amount of target production: Setup the production amount you required , […]

Read more

2.11.3 Monitoring Setting of Injection Molding Machine – Part 2

Path: F10 next –> F2 monitor –> F4 test 2/F5 test 3   F4 test 2   F5 test 3   This monitoring screen allows you to compare the most important production cycle parameters. Use this screen to compare production parameter deviation during machine operation. The parameter comparison of different […]

Read more

2.11.2 Monitoring Setting of Injection Molding Machine – Part 1

Path: F10 next –> F2 monitor –> F3 test 1 The HMI and controller provide you with an automatic monitoring and alarm system. The system allows you to set a desired operating range with upper and lower limits (Delta Values) for each production parameter. Once the current parameter value exceeded […]

Read more

2.11.1 Alarm Display of Powerjet Injection Molding Machine

Path to get to alarm display screen: F10 next –> F2 monitor –> F2 alarm   Display Start No: The screen displays 8 error messages at a time. If you want to refer to the previous recorded errors you can enter here the error number for the first error to […]

Read more

2.10.3 Fast set mold adjustment parameters settings

In this article, we will show you the path to get to fast set mold adjustment parameters settings screen. So you can adjust all cor-responsible parameters of the mold adjustment according to your actual production. Path: screen –> F9 fast set –> F4parameters This screen consists of all cor-responsible parameters […]

Read more

Subscription

    Keep in touch with POWERJET and get our latest news:

    Your email address is safe with us.

    Contact Us

    Address: NO.5 Chuangxin Xi Road,
    Leping Industrial Park of Shanshui,
    Foshan City, Guangdong, China
    Phone: +86-139 2508 7612
    Fax: +86-757-8669 7566
    Email: marketing[@]powerjet-machinery.com